Plumbing pressure testing
Pressure and head tests, smoke testing, and camera inspections when needed or requested.
- Licensed, bonded & insured
- Bilingual crews
- Townhomes & row houses
How a plumbing system proves it holds
Testing is the last easy chance to find a bad joint. Once the drywall is up, every leak comes with a patch-and-paint bill on top of the repair.
How is the drain and vent system tested?
With water or air. For a water test, the system is filled to its highest opening, and under the Uniform Plumbing Code no section can be tested with less than a 10-foot head of water. For an air test, the system is pressurized to 5 psi and has to hold for at least 15 minutes without any air being added.
How is the water supply tested?
Under water pressure at least as high as the pressure the system will run at, held for at least 15 minutes without leaking. The code allows a 50 psi air test instead, but not on plastic pipe, so plastic supply systems are tested with water.
What is a smoke test for?
Finding leaks you can't see. Non-toxic smoke is pushed into the drain and vent system, and it shows up wherever the system isn't sealed, from a cracked fitting to a loose cleanout cap. It's especially useful for tracking down a sewer gas smell, because the smoke goes where the gas would.
When does a camera inspection make sense on new work?
When you want to see inside a line before it's buried or handed over: checking a side sewer for sags or offset joints, or a line that may have been hit during other site work. The recording also gives the builder a record of the line's condition.
Sources: UpCodes: Uniform Plumbing Code, testing the drainage and vent system, UpCodes: Uniform Plumbing Code 609, testing water supply piping.
Planning a build?